Climatronics»çÀÇ ¿Âµµ ¼¾¼­º° ±Ô°Ý
Air, Water/SoilP/N's 100093 (102090*)100093-4 Expanded Range P/N 100093-2 (102096*) Fast ResponseP/N 100093-3 Platinum 4-WireP/N100826 (102092*)
Accuracy ¡¾0.15¡ÆCover full range ¡¾0.10¡ÆCover full range ¡¾0.15¡ÆCover full range ¡¾0.1¡ÆC
Range -30.0¡Æ to 50.0¡ÆC -50.0¡Æ to 50.0¡ÆC -30.0¡Æ to 50.0¡ÆC -50.0 to 50.0¡ÆC
Time ConstantInterchangeability 3.6s(¡¾0.15¡ÆC) 3.6s(¡¾0.10¡ÆC) 0.6s(¡¾0.15¡ÆC) 5.5scan be compensated
Linearity ¡¾0.16¡ÆC ¡¾0.16¡ÆC ¡¾0.16¡ÆC included in accuracy
Length 4.5 in (11.4 cm)1.0 in (2.54 cm) 4.5 in. (11.4 cm) 1-7/8 in (4.8 cm) 6.0 in (15.2 cm)
Climatronics»çÀÇ ½Àµµ ¼¾¼­º° ±Ô°Ý
P/N 102273 P/N 102425
Accuracy <+/- 1% RH from 0 to 100% <+/- 3% RH from 10 to 90 %
Repeatability +/-0.3% RH
Operating Range 0 to 100 % 0 to 100 %
Operating Temperature Range -40¡Æ to 60¡ÆC -10¡Æ to 60¡ÆC
Long Term Stability +/-1% over 12 months +/- 5% RH over 24 months
Response Time (without filter) 10 seconds 10 seconds
Excitation Power 4.8 to 30 VDC; 2.5 mA @ 12 VDC 7 to 28 VDC; 2 mA @ 12 VDC
Length 10.12 in (257 mm) 2.7 in (69 mm)